Air Compressor, Dental Air Compressor, Dental Equipment manufacturer / supplier in China, offering Dental Air Compressor Oil Less Air Compressor, Dental Colorful 2/4 Holes LED High Speed Handpiece (Colorful-TUP), Ceramic Bearing Dental Handpiece Cartridge and so on.

(/ )

Supplier Homepage Product Dental equipment air compressor Dental Air Compressor Oil Less Air Compressor

Dental Air Compressor Oil Less Air Compressor

Purchase Qty.:
(Pieces)
1-9 10+
FOB Unit Price: US $850 US $780
Purchase Qty. (Pieces) FOB Unit Price
1-9 US $850
10+ US $780
Get Latest Price
Production Capacity: 3, 00PCS/Month
Transport Package: Standard Export Carton
Payment Terms: T/T, Paypal, Money Gram, Western Union

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Brand: Dts Dental
  • Power: 550W
  • Discharge Capacity: 70L/Min
  • Noise: 60dB
  • Origin: Guangdong
  • Supply Voltage: 220V
  • Pressure: 0.45-0.8MPa
  • Air Container Volume: 30L
  • Trademark: DTS
Product Description

Feature
1,Main air container adopt Automotive paint process, High temperature resistant, Anti corrosion, long lift time span, beautiful appearance.
2,Special power switch setting, Overcurrent protection device, protect from over voltage and over current.
3,Low noise,slight vibration, provide a quiet and convenient environment

With the features of low noise, energy-saving, environmental protection and used securely, this machine is widely used in the filds of medical, sanitation, foodstuff, scientific testing and so forth.

NO.Trouble symptomsTrouble analysisRemedy
1The compressor fails to work,the motor does not buzz normallyThere is on power in the socket or the power switch is not turned on.Turn on the power.
The pressure controller is not connected Check the wiring of hte pressure controller
2The compressor stops before the maximum pressure in reachedThe set value of the pressure switch is lowAdjust the settings to the required value .
3The machine fails to start normally,the compressor does not run,or runs a moment and stops itself,the motor buzzes.The voltage is too low1.Use a voltage stabilizer.          
2.Wait for the voltage to become normal before strat to use. 
More troubleContact the manufacturer
4The compressor can work continually,but the pressure can't reach the maximum value or the time maintaining the maximum value in increased.The Engraving Machine or the pipeline leaks airCheck each joint(soap water may be used) for any air leakage
Compressor head troubleContact the manufacturer
5The air pressure in decreased after the machine stops.Air leaks from joint of the air reservoirAdd adhesive,tighten joint.
Reverse air leakage from the unsealed check value 
1.Wash and clean the value core,or replace it.                   
2.Replace the spring or check the value.

6
The compressor does not stop when the maximum pressure setting in exceeded.Pressure controller troubleAdjust or replace the pressure controller.
7The safety value releases air within the compressor's working pressure range.The spring force of the safety value is weak,the adjustable nut is loose.Adjust the safety value adjusting nut to the position where the safety value release air under working pressure,then lock the nut.